- home > Supply > Chifeng high-voltage isolation switch _ Huayi Electric Power (certified) _ disconnectors
Information Name: | Chifeng high-voltage isolation switch _ Huayi Electric Power (certified) _ disconnectors |
Published: | 2015-03-23 |
Validity: | 0 |
Specifications: | Limited |
Quantity: | |
Price Description: | |
Detailed Product Description: | The correct order of operations isolation switch: (1) First isolation switch in the operation, you should first check the appropriate circuit breaker in the off position indeed, in order to prevent a negative Hera, co-isolation switch. (2) line stop, when the power is in the order must pull together isolation switch. When a power outage, you must first pull circuit breakers, disconnectors pull the line side Jilin pressure isolation switch, then pull the bus side of the isolation switch. Power transmission and power operation sequence in reverse order. This is because the misuse of Dalian high-voltage isolation switch, according to the above procedure can reduce the scope of the accident, Harbin high-voltage isolation switch, to avoid artificially expanded to make the bus accident. (3) operations, such as found seriously damaged insulator, isolating switch gear lever serious damage and other serious defects, may not operate. (4) isolation switch operation, there should be the duty officer at the scene-by-phase check points, closing position, over the same period, the contact depth contacts and other projects, to ensure the correct operation of the isolation switch, the correct position. (5) should generally be operated isolating switch in the main control room. When the remote control electrical operation failure in the field can be manually or electrically operated locally, but must seek permission from owners or technical person in charge, and in the case of on-site supervision of the situation can take place. (6) disconnectors, grounding switch and circuit breaker between the installation to prevent misuse of electrical, electromagnetic and institutions locking device. Switching operations, according to a certain order. If the locking device malfunction or disconnectors and earthing switches does not operate properly, you must strictly in accordance with the requirements of lockout condition check the appropriate circuit breakers, disconnectors position status only after checking the correct order to lift the lockout operation. Movement isolation switch contacts should be aligned, otherwise the closing time will be next to the hammer, so that after closing and moving contacts the contact surface pressure is uneven, resulting in poor contact. Chifeng high-voltage isolation switch _ Huayi Electric Power (certified) _ isolating switch is provided by Xian Huayi power plant. Xian Huayi power plant (www.xahy.com) is a leader in Xi'an, high voltage circuit breakers, over the years, the company is implementing the scientific management, innovation and development, the principle of honesty and trustworthiness, and satisfy customer needs. Huayi power in leadership with the staff warmly welcome all inquiries negotiations to create electricity Huayi a better future. |
Admin>>>
You are the 25203 visitor
Copyright © GuangDong ICP No. 10089450, Xian Huayi power plant All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 25203 visitor
Copyright © GuangDong ICP No. 10089450, Xian Huayi power plant All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility