Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13635014

- Product Categories
- Friendly Links
- home > Supply > Hanzhong 35kv high voltage isolation switch, Huayi Electric Power (certified), disconnectors
Information Name: | Hanzhong 35kv high voltage isolation switch, Huayi Electric Power (certified), disconnectors |
Published: | 2015-01-05 |
Validity: | 0 |
Specifications: | Limited |
Quantity: | |
Price Description: | |
Detailed Product Description: | The main role of an isolation switch) after opening, the establishment of a reliable insulation gap Shangluo 35kv high voltage isolation switch, you will need repair equipment or power lines and dotted with a clear disconnect Hanzhong 35kv high voltage isolation switch, in order to ensure the maintenance personnel and equipment security. Disconnectors 2) Depending on the operating needs for access lines. 3) can be used to open, close the line in a small current, such as the casing, bus connector, short cable charging current, voltage capacitor capacitance switches are current, dual-bus for access when the circulation and voltage transformer magnetizing current and so on. 4) depending on the circumstances of different types of structures can be used to open, close certain load capacity of the transformer magnetizing current. High voltage isolation switch according to the different installation methods, can be divided into outdoor and indoor high-pressure isolation switch isolation switch isolation switch refused points, closing what should I do? A: (1) due to the axle pin off, wedge bolt exit, cast iron fracture mechanical failure, or because of an electrical circuit fault may occur with the operating mechanism of touch Tongchuan Arbor 10kv high voltage isolation switch, causing the isolation switch refusal closing, this time Applications insulated rod operation, or in the case of personal safety, use a wrench to rotate the shaft of each phase isolation switch. (2) refusing to trip. When the isolation switch will not pull out when the actuator is the case of the ice to freeze, you can gently shake and observe the various parts of the support insulator and institutions in order according to where the deformation and displacement, identify obstacles location. If the obstacle location occurs in the contact portion isolating switch should not be forcibly opened, otherwise the support insulator may be affected by damage caused by a serious accident, then the only way to change the operation of the equipment to be addressed. Hanzhong 35kv high voltage isolation switch, Huayi Electric Power (certified), isolating switch is provided by Xian Huayi power plant. Xian Huayi power plant (www.xahy.com) is a leader in Xi'an, high voltage circuit breakers, over the years, the company is implementing the scientific management, innovation and development, the principle of honesty and trustworthiness, and satisfy customer needs. Huayi power in leadership with the staff warmly welcome all inquiries negotiations to create electricity Huayi a better future. |
Admin>>>
You are the 25203 visitor
Copyright © GuangDong ICP No. 10089450, Xian Huayi power plant All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 25203 visitor
Copyright © GuangDong ICP No. 10089450, Xian Huayi power plant All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility